Ankara Chiller Maintenance: Winter Freeze Protection and Summer Preparation

Ankara Chiller Maintenance: Winter Freeze Protection and Summer Preparation

In Ankara chillers mostly run on rooftops or in open areas, so frost in winter and dust and high outdoor temperatures in summer are the main maintenance concerns.

In shortChiller maintenance in Ankara should be planned at least twice a year: freeze protection in autumn (glycol ratio, draining, heater check) and summer preparation in spring (condenser cleaning, refrigerant and compressor checks). YOİ Mühendislik provides maintenance and breakdown service for chillers in public, hospital, plaza and industrial facilities across Ankara.
Recommended maintenance period
October–November (winter preparation) and March–May (summer preparation)
Critical risk
Freezing of the evaporator and hydraulic line in winter
Typical use
Public campuses, hospitals, plazas, shopping malls, industrial-zone process cooling
System types
Air-cooled, water-cooled (with tower), screw, scroll, centrifugal

About Ankara Chiller Maintenance: Winter Freeze Protection and Summer Preparation

A large share of big buildings in Ankara are cooled by central chiller–fan coil or chiller–air handling unit systems. Ministries and public campuses, hospitals, universities, plazas and shopping malls lead this building type. In the industrial zones of OSTİM, İvedik and Sincan, chillers are used less for comfort cooling and more for process water, mold and machine cooling, and run for most of the year.

The city's continental climate creates two separate risk periods for chillers. In winter, night temperatures fall below zero; if the water left in the evaporator, piping or hydraulic module of an outdoor air-cooled chiller freezes, the heat exchanger can crack. That is why, in autumn, the glycol ratio should be measured, the water drained in a controlled way if the system will not be used, and the crankcase and antifreeze heaters and flow switches verified. For process chillers that run all winter, low ambient temperature control is also important.

In summer, rising outdoor temperatures and the dust, pollen and steppe particles carried by dry air clog condenser coils quickly. A dirty condenser causes high-pressure faults, strains the compressor and raises energy consumption. In pre-summer maintenance in Ankara, condenser washing, fan and motor checks, refrigerant pressures, compressor currents and electrical connections are handled together.

Chiller maintenance in Ankara should not be limited to the unit itself. Circulation pumps, expansion tank, air vents, strainers and the water treatment setup directly affect system efficiency. Because the city's mains water can leave scale, scale and sediment buildup in condenser tubes and cooling towers of water-cooled systems should be monitored regularly.

Our services for Ankara Chiller Maintenance

How do we work?

We respond to chiller breakdowns within Ankara the same day. In periodic maintenance we assess the unit and the hydraulic system together and enter the measured values in the maintenance form, so they can be compared with the previous visit. For facilities under an annual contract we schedule winter and summer preparation. Compressor overhaul, refrigerant leak detection and repair are also among our services. For the full list of items checked, see our chiller maintenance page; you can submit a request with our maintenance form.

Free maintenance and service forms (PDF)
Checklist forms for chillers, fan coils, air handling units, VRF and other equipment.
See the forms

Frequently asked questions

What should we do if we shut the chiller down for winter?

If there is no glycol in the system or the ratio is insufficient, the water must be drained in a controlled way or brought to the right ratio. In Ankara this is recommended in autumn, before the first frosts.

How often should the glycol ratio be checked?

At least once a year, before winter. If water has been added to the system the ratio may have dropped, so it should be measured again.

The chiller trips on high pressure at the start of summer. What could the cause be?

The most common causes are a dirty condenser coil and fan problems. Refrigerant charge, sensors and the electrical side should also be checked.

Do you also service process chillers in industrial facilities?

Yes. We provide maintenance and breakdown service for process cooling chillers, mainly in the OSB industrial zones of OSTİM, İvedik and Sincan.

Nearby areas

Compressor overhaul and replacement

When a compressor fails we first measure the cause: oil analysis, megger, current and pressure values. Overhaul is recommended for bearing and seal wear; compressor replacement together with system cleaning for winding burnout.

Screw compressor brands and overhaul steps What to watch for when replacing

Maintenance plan for Ankara Chiller Maintenance

Site survey, equipment inventory and written quote. Ankara headquarters, serving all of Türkiye.

Bize ulaşın

Teklif alın, aynı gün dönüş yapalım

Cihazınızı ve ihtiyacınızı kısaca yazın; ilgili mühendisimiz sizi arasın. Arıza, bakım, sözleşme veya yeni cihaz için tek adres.

Yetkili ServisTSE Hizmet Yeterlilik Belgesi2009'dan beri

Hızlı teklif formu

Form WhatsApp mesajı olarak iletilir.

Detaylı talep için teklif formunu kullanabilirsiniz.