Server cabinets and cooling airflow in a data center

What is a precision air conditioner? How do close control air conditioning systems work?

YOİ Mühendislik technical team5 min readBrand and system guideOctober 29, 2026
In shortA precision air conditioner (close control air conditioner) is designed to keep temperature and humidity within a narrow range without interruption, every day of the year, in places such as data centers, server rooms and laboratories. Compared with a comfort air conditioner, it operates with higher airflow and sensible cooling ratio, controls humidity, is installed redundantly and is connected to an alarm system.

Difference between a precision air conditioner and a comfort air conditioner

Office or home air conditioners are designed for human comfort; they run at certain hours of the day and also remove part of the air's moisture. Servers and electronic equipment, on the other hand, mainly produce sensible heat and run day and night. Precision air conditioners are designed with high airflow, a high sensible heat ratio and continuous operation in mind to meet this load.

Comfort air conditionerPrecision air conditioning
Working timeSeasonal, certain hours of the dayEvery day of the year, uninterrupted
CheckTemperature onlyTemperature and humidity, narrow tolerance
Airflow rateLow to mediumHigh
RedundancyGenerally noneN+1 or more
MonitoringControlAlarm, BMS and remote monitoring

Precision air conditioner types

Let's evaluate your server room's cooling together

Tell us the unit brand, quantity and room load; we will get back to you for a maintenance plan or capacity check.

What range are temperature and humidity kept in?

The common reference in data centers is the ranges recommended by ASHRAE; the recommended temperature range for server inlet air is generally taken as 18-27 °C. If humidity gets too low, there is a risk of static electricity; if too high, a risk of condensation. Exact values are determined according to the equipment manufacturer's and the facility's conditions. We covered humidity management in our article precision air conditioner humidity control.

Why is redundancy a must?

In a server room, the shutdown of a single air conditioner can trigger a temperature alarm within minutes. That is why at least one more unit than needed (N+1) is installed and the units are run in rotation. Details: N+1 redundant operation.

Precision air conditioner brands

The brands we encounter most often in the field include Liebert (Vertiv), Stulz, Uniflair (Schneider Electric), CIAT, Hiross, Rittal, Huawei, Airedale and Emicon. We provide maintenance and repair for these brands as an independent technical service: Liebert precision air conditioner service, Stulz precision air conditioner service, Uniflair, CIAT precision air conditioner service.

Precision air conditioner maintenance

During maintenance, the alarm history is read, sensors are compared with a reference measurement, and filters, fans, humidifier and drain are checked; on DX units the refrigerant circuit is checked, and on chilled water units the valve and water flow are measured. For the scope, see our precision air conditioner service page and the maintenance form.

Frequently asked questions

What does precision air conditioner mean?

It is an air conditioner designed to control temperature and humidity within a narrow range, without interruption, every day of the year. It is also referred to as a close control or CRAC unit.

Can a normal split air conditioner be installed in a server room?

It can be used as a temporary solution in small rooms; however, split air conditioners are not designed for continuous operation, humidity control and redundancy. A precision air conditioner is recommended for critical rooms.

What is the difference between CRAC and CRAH?

A CRAC is a direct expansion unit with its own compressor. A CRAH has no compressor and runs on chilled water from a chiller.

How often is precision air conditioner maintenance done?

For units that run continuously, a periodic check every three months and comprehensive maintenance once a year are generally recommended.

Which precision air conditioner brands do you service?

We provide maintenance and repair as an independent technical service for Liebert (Vertiv), Stulz, Uniflair, CIAT, Hiross, Rittal, Huawei, Airedale and other brands.

Related calculators

See all calculators (31) →

what is a precision air conditionerprecision air conditionerclose control air conditionerprecision air conditioning systemsdata center air conditioningserver room air conditioningserver room air conditionerwhat is a cracin-row precision air conditionerprecision air conditioner service
Bize ulaşın

Teklif alın, aynı gün dönüş yapalım

Cihazınızı ve ihtiyacınızı kısaca yazın; ilgili mühendisimiz sizi arasın. Arıza, bakım, sözleşme veya yeni cihaz için tek adres.

Yetkili ServisTSE Hizmet Yeterlilik Belgesi2009'dan beri

Hızlı teklif formu

Form WhatsApp mesajı olarak iletilir.

Detaylı talep için teklif formunu kullanabilirsiniz.